High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
| Property | Value | Notes |
|---|---|---|
| Common abbreviation | HPLC | High-performance liquid chromatography |
| Separation basis | Differential partitioning | Between liquid mobile phase and solid stationary phase |
| Common mode | Reverse phase | Nonpolar column, polar mobile phase |
| Typical detector | UV-Vis absorbance | Widely used for compounds with chromophores |
| Typical column particle size | 2–5 µm | Smaller particles can improve resolution |
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Wills Professor of Physics, University of Bristol. For services to Physics. Professor Henry John Evans. For services to Medical Research. James Stuart Fair, Chairman, Dundee Teaching Hospitals NHS Trust. For services to Health Care. Jonathan Farquharson, lately Legal Commissioner, Charity Commission. Thomas Hugh Francis Farrell, , Pro-Chancellor and Chairman of Council, University of Hull. For services to Higher Education. David Geoffrey Nigel Filkin, Secretary, Association of District Councils. For services to Local Government. Stanley Fishman, President, Cinema Exhibitors' Association. For services to the Film Industry. Frederick Forsyth, Writer. For services to Literature. Michael John Ernest Frye, Chief Executive, B. Elliott plc. For services to Business. Professor Charles Albert Eric Goodhart, Professor of Banking and Finance, London School of Economics. For services to Monetary Economics. Peter James Grant, Chairman, Highlands and Islands Airports Ltd. For services to Industry. Paul Frederick Gribble. For political service. Ewan William Harper. For services to the Church of England. Derek James Harrington, Deputy Chairman and Chief Executive, Port of Felixstowe Ltd., and Director, Hutchison International Port Holdings. For services to the Ports Industry. Peregrine Andrew Morny Cavendish, Marquess of Hartington, lately Senior Steward of the Jockey Club and Chairman, British Horse Racing Board. For services to Horse Racing. David Hewitt. For services to the Community. Pamela Jean Hibbs, , Chief Nurse and Director of Quality Assurance, Royal Hospitals NHS Trust, London.
=== History of claimed benefits === In 1888, an article appeared in Scientific American discussing potential germicidal activity of tobacco smoke providing immunity against yellow fever epidemic of Florida inspiring research in the lab of Vincenzo Tassinari at the Hygienic Institute of the University of Pisa, who explored the antimicrobial activity against pathogens including Bacillus anthracis, Mycobacterium tuberculosis, Bacillus prodigiosus, Staphylococcus aureus, and others. Carbon monoxide is a bioactive component of tobacco smoke that has been explored for its antimicrobial properties against many of these pathogens. On epidemiological grounds, unexpected correlations between smoking and favorable outcomes initially emerged in the context of cardiovascular disease, where they were described as a smoker's paradox (or smoking paradox). The term smoker's paradox was coined in 1995 in relation to reports that smokers appeared to have unexpectedly good short-term outcomes following acute coronary syndrome or stroke. One of the first reports of an apparent smoker's paradox was published in 1968 based on an observation of relatively decreased mortality in smokers one month after experiencing acute myocardial infarction. In the same year, a case–control study first suggested a possible protective role in Parkinson's disease. Historical claims of possible benefits in schizophrenia, whereby smoking was thought to ameliorate cognitive symptoms, are not supported by current evidence.
=== 9 April === Ukraine started electricity exports for the first time since six months after the invasion. Energy exports had been stopped due to multiple strikes on the electrical infrastructure. Ukrainian Energy Minister Herman Halushchenko stated that the electrical system had been producing extra capacity for almost two months.
Fujirebio is a Japanese multinational in vitro diagnostics (IVD) company, founded in 1950 and headquartered in Tokyo, Japan. The company develops, manufactures, and markets IVD testing products — including reagents, instruments, and software — for clinical diagnostics and research use. Fujirebio operates offices in Asia, Europe, and the United States, and maintains a broad international distribution network, with manufacturing facilities in Japan, Europe, and the United States. The company employs more than 1,400 people globally. Fujirebio operates an open business model in which it develops novel biomarkers and diagnostic content, validates them using its own fully-automated Lumipulse® chemiluminescent enzyme immunoassay (CLEIA) platform, and distributes them globally through partnerships and a Contract Development and Manufacturing Organization (CDMO) model — providing development, manufacturing, and regulatory services to third-party diagnostic companies. The company’s principal areas of expertise include oncology, infectious diseases, and neurological disorders. In May 2025, Fujirebio received FDA 510(k) clearance for the Lumipulse® G pTau 217/β-Amyloid 1-42 Plasma Ratio test, the first FDA-cleared blood-based IVD test to aid in identifying amyloid pathology associated with Alzheimer’s disease. In 2022, Fujirebio acquired ADx NeuroSciences, a Belgian biotech company specializing in neurological biomarker research, for €40 million. Fujirebio is a consolidated subsidiary of H.U. Group Holdings, Inc.
Sources: en.wikipedia.org
=== Neurotoxicity === Selegiline has been reported to protect against the damage caused by the potent dopaminergic and/or noradrenergic neurotoxins 6-hydroxydopamine (6-OHDA), N-(2-chloroethyl)-N-ethyl-2-bromobenzylamine (DSP-4), and 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) in animals. Conversely, selegiline is ineffective in protecting against the serotonergic and noradrenergic neurotoxin 5,7-dihydroxytryptamine (5,7-DHT). Selegiline has also been reported to protect against methylenedioxymethamphetamine (MDMA)-induced serotonergic neurotoxicity in rodents. The serotonergic neurotoxicity of MDMA appears to be dependent on release of dopamine and its subsequent metabolism by MAO-B within serotonergic neurons into hydroxyl radicals, which is blocked by MAO-B inhibition. Likewise, selegiline prevented the serotonergic neurotoxicity of a combination of methylenedioxyaminoindane (MDAI) and dextroamphetamine. Conversely, selegiline failed to reduce the serotonergic neurotoxicity caused by fenfluramine and either did not affect or potentiated the serotonergic neurotoxicity caused by para-chloroamphetamine (PCA). In addition, findings are mixed and conflicting on whether selegiline prevents amphetamine- and methamphetamine-induced dopaminergic neurotoxicity in rodents. Although MAO-B-selective doses of selegiline protect against MDMA-induced serotonergic neurotoxicity in rodents, combination of amphetamines like MDMA with MAOIs, including selegiline, can produce serious complications, including serotonin syndrome, hypertensive crisis, and death.
Hazard research is published: a systematic analysis estimates 4.71 million deaths were associated with bacterial antimicrobial resistance (AMR) in 2021, estimates the trends in AMR mortality since 1990, and finds AMR could cause 39 million deaths worldwide between 2025 and 2050 (16 Sep.), researchers publish data on the detection of over 3000 food contact materials (FCMs) in humans (17 Sep.), and a study finds 189 (21%) of potential breast carcinogens have been measured in FCMs, indicating at least 76 of these leach into foods of populations (24 Sep.).
=== 1990s === In 1990, following the Grace's Grace Energy public offering in 1989, Grace Energy purchased all of the minority shares of its common stock of its Grace Drilling from Panhandle Eastern Corporation, which gave Grace Energy 99.45% ownership of Grace Drilling. In 1992, Grace sold its 21%-percent interest of Grace Cocoa (Grace Cocoa Associates, LP,), for $300 million. Grace Cocoa was classified as a discontinued operation by Grace in 1993, but due to market conditions, the Grace later sold the rest of the company along with its paper drying, polymer, and filtration units in 1996 for over $300 million. In 1995, Albert Costello became the CEO of the company, replacing J. Peter Grace, as well as became the new president, replacing J.P. Bolduc. Costello was the former CEO and chairman of the board at American Cyanamid (1993-1994). Bolduc (CEO from 1993-1995) was considered to have successfully sold off some of the unprofitable noncore businesses and to have expanded some of the successful businesses within the company at that point in time.
Sources: en.wikipedia.org
HPLC testing measures the presence and amount of one or more compounds in a liquid sample. It separates mixture components and records detector responses as peaks, which are compared with reference standards. Results are usually reported as concentrations or relative percentages.
Retention time is the interval between sample injection and the detector response for a given compound. It depends on the compound's interactions with the stationary and mobile phases under set conditions. Matching a retention time to a standard supports tentative identification but is not always unique.
HPLC alone can separate unknown compounds and provide retention times, but it often cannot identify them with certainty. Coupling HPLC to mass spectrometry gives mass information that improves identification. Confirmation usually requires comparison with reference standards or complementary techniques.
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.